A twin case study

We work with a number of customers who have similar assets across several sites. This can be of help when considering the likely cause of a problem, but recently we had a reminder that all our samples are individuals and the analysis process should be followed independently and without preconceptions.

On the surface the problems appeared identical – an off-shore pump with a lubricating and a seal oil circuit.

The problem:

Reducing lube oil viscosity – suspected ingress of seal oil. Samples of new and in-service seal and lubricating oil were provided.

Routine oil analysis and FTIR spectroscopy were performed. The answers however were not the same.

Site A: Virgin lube oil was found to be of a lower viscosity grade than that expected. It matched the in-service lubricating oil, explaining the low viscosity. No seal oil ingress was found. Incorrect lube oil was being used.

Site B: Virgin lube oil was in spec. FTIR spectroscopy confirmed ingress of seal oil into the lubricating oil system. Additional analysis of a seal and lube oil mixture confirmed these findings.

Conclusion

While past experience may suggest a likely cause of the problem it does not guarantee that the actual issue will be the same this time. So take the necessary steps to investigate and determine the true cause in each and every case. Otherwise you may find yourself topping up with incorrect oil all along, wondering why it stays too thin!

Want to learn more about the power of FTIR? 

See our Example FTIR Report and pages 14 and 15 of our Brochure

You may also like

  • Thinking of starting an oil analysis programme?

    Thinking of starting an oil analysis programme?

    If you are visiting our web site for the first time you may be looking at starting an oil analysis programme, but you may also need to justify the cost to senior management. This article on Justifying an Oil Analysis Program may provide some of the arguments you’ve been looking for. Remember you can always.

    Continue reading October 3rd 2012
  • Online Results Database

    Online Results Database

    As many of you are aware we have switched over to our web portal for reporting oil analysis results. If you’ve sent some samples recently you would have been issued with login details. If you haven’t seen the portal yet then below is a tiny preview. Feel free to drop us a line if youRead More

    Continue reading August 28th 2015
  • OAS moves to new premises

    OAS moves to new premises

    OAS have moved to new state of the art premises not far away from the original location.

    Continue reading January 25th 2019